Bill Akers wrote:

> Windows and macs are sending print jobs to the spoolers via LPD. Some of the 
> jobs hang up on the spoolers with missing resource:
>   
> Res: 1 0 ProcSet "CIDInit" 0 0
> 
> I saw a former post about problems with CIDInit, and I have tried creating an 
> empty cache file "/usr/share/ppr/cache/procset/CIDInit-0-0" on the spooler to 
> get around this problem.  But it doesn't fix the issue.  The print jobs just 
> stay on the spooler.

The former problem is corrected in current versions of PPR.  This is a 
new one due to a defect in certain versions of Adobe Acrobat reader. 
The problem is that the word "procset" is in the wrong case.  The 
workaround is to do this:

mkdir /usr/share/ppr/cache/ProcSet
touch /usr/shrae/ppr/cache/ProcSet/CIDInit

================================================================
David Chappell			David.Chappell@Mail.Trincoll.Edu